Cold Cathode Germicidal UV Lamps
The cold cathode germicidal UV lamp is easy-to-install due to its compact structure, and it consumes little power when working. As a CE and RoHS certificated product, it is able to work for 15000 hours, and it can be started up by either AC or DC power supply. In general, there are two commonly used types which are linear germicidal lamp (GCL) and U-shaped germicidal lamp (GCU).
Function
Ozone free UV lamp gives out 253.7nm UV light, while ozone generating UV lamp provides both 185nm and 253.7nm UV light. With different wavelengths, these UV light could inactivate microorganisms in a few minutes, though in different ways.
Application
Owing to the abovementioned properties, our germicidal UV lamps are particularly suitable for refrigerators, disinfection cabinets, microwave ovens, toothbrush sanitizers, make up brush sanitizers and other small electrical devices.
Germicidal UV Lamp for Wall-mounted Toothbrush Sanitizer
Model |
Input voltage |
Lamp voltage |
Lamp current |
Lamp power |
UV wavelength |
Useful life |
GC110L5VH |
9VDC |
400±20VAC |
2.5mA |
1W |
253.7nm+185nm |
>15000h |
Germicidal UV Lamp for Portable Toothbrush Sanitizer
Model |
Input voltage |
Lamp voltage |
Lamp current |
Lamp power |
UV wavelength |
Useful life |
GC45L5VH |
3VDC |
300±20VAC |
2mA |
0.6W |
253.7nm+185nm |
>15000h |
GC50L5VH |
3VDC |
300±20VAC |
2mA |
0.7W |
253.7nm+185nm |
>15000h |
Germicidal UV Lamp for Tubby Toothbrush Sanitizer
Model |
Input voltage |
Lamp voltage |
Lamp current |
Lamp power |
UV wavelength |
Useful life |
GC54U4VH |
4.5VDC |
400±20VAC |
2.8mA |
1.2W |
253.7nm+185nm |
>15000h |
GC90U4VH |
12VDC |
400±20VAC |
5mA |
2W |
253.7nm |
>15000h |
GC100U4VH |
12VDC |
400±20VAC |
5mA |
2W |
253.7nm |
>15000h |
GCU
OD (mm) |
Length |
Lamp current |
Lamp voltage |
Lamp power |
UV output |
Useful life |
4, 5 or 6mm |
40~60mm |
2~5mA |
200~300V |
0.8~1.5W |
8000μW/cm2 |
15000h |
80~100mm |
2~5mA |
300~450V |
1.5~2.0W |
8000μW/cm2 |
15000h |
120~150mm |
3~5mA |
450~600V |
2.0~3.0W |
8000μW/cm2 |
15000h |
200~250mm |
4~6mA |
600~850V |
3.0~4.0W |
8000μW/cm2 |
15000h |
Note: Tube diameter and length can be customized.
GCL
OD |
Length |
Lamp current |
Lamp voltage |
Lamp power |
UV output |
Useful life |
4, 5, 6, 9 or 12mm |
45~60mm |
4~5mA |
150~250V |
0.6~1.2W |
>3000μW/cm2 |
15000h |
80~100mm |
4~5mA |
250~300V |
1.0~1.5W |
>3000μW/cm2 |
15000h |
120~180mm |
4~5mA |
300~400V |
1.5~2.0W |
>3000μW/cm2 |
15000h |
200~300mm |
4~6mA |
400~600V |
2.0~2.5W |
>3000μW/cm2 |
15000h |
300~400mm |
4.5~6mA |
600~800V |
2.5~3.5W |
>3000μW/cm2 |
15000h |